G.O.A.T. Lab Test Results
Genesis Organic Assurance Testing was contracted by AgriAir to do a controlled study on the effectiveness of their Hydrogen Peroxide generating air purification unit. We have tried to insure impartiality in sampling. We make no claims on behalf of the Manufacturer or Distributor of this product. The following are actual counts from Yeast/Mold and Aerobic Plates. We found no other concerns on initial or subsequent tests. The system works as advertised.
For questions or concerns about testing process or procedures please contact: Dana Luce at G.O.A.T. Labs – 360-513-9377.
Test Scenario:
Prove effectiveness of AgriAir Purification equipment on microbial and mold eradication in indoor Cannabis grow facilities
Temperature: 69 – 73° F
Humidity: 45 – 65%
CO2: 1400 ppm
Room Size: 40,000 cubic feet
# of Plants: 370 – 420
Room 1 | |||||
Room Swab | Baseline | 3 Days | 1 Week | 3 Weeks | |
Aerobic | Fail – TMTC | 3,200 | 1,000 | 1,000 | |
Mold | Fail – TMTC | 126,000 | 700 | 0 | |
Filter Swab | Baseline | 3 Days | 1 Week | 3 Weeks | |
Aerobic | 34,000 | 73,000 | 3,000 | ||
Mold | 1,900 | 30,700 | 0 |
Room 4 | |||||
Room Swab | Baseline | 3 Days | 1 Week | 3 Weeks | |
Aerobic | 81,000 | 35,000 | 5,000 | 2,000 | |
Mold | Fail – TMTC | 6,400 | 100 | 100 | |
Filter Swab | Baseline | 3 Days | 1 Week | 3 Weeks | |
Aerobic | 21,000 | 94,000 | 5,000 | ||
Mold | 2,000 | 2,700 | 0 |